Publikationen 2020
RWTH Aachen Universitätsbibliothek
- M. Asseln, J. Eschweiler, A. Trepczynski, P. Damm & K. Radermacher: Evaluation and validation of 2D biomechanical models of the knee for radiograph-based preoperative planning in total knee arthroplasty. PLOS ONE, 2020, 15(1), pp. 1-16 [DOI: 10.1371/journal.pone.0227272]
- S. Drobinsky, M. Verjans, P. Schleer, B. Kolk, H. Bensiek, K. Radermacher & A. Janß: Workflow and Human-Centered Risk Analysis for Novel Mechatronic Rescue Aids. Current Directions in Biomedical Engineering, 6(3), 2020, pp. 1-4 [DOI: 10.1515/cdbme-2020-3156]
- M.C.M. Fischer, S.A.G.A. Grothues, J. Habor, M. de la Fuente & K. Radermacher: A robust method for automatic identification of femoral landmarks, axes, planes and bone coordinate systems using surface models. Scientific Reports, 2020, 10(20859), pp. 1-11 [DOI: 10.1038/s41598-020-77479-z]
- M.C.M. Fischer, K. Tokunaga, M. Okamoto, J. Habor & K. Radermacher: Preoperative factors improving the prediction of the postoperative sagittal orientation of the pelvis in standing position after total hip arthroplasty. Scientific Reports, 2020, 10(15944), pp. 1-10 [DOI: 10.1038/s41598-020-72782-1]
- C. Goffin: Modellbasierte Biomechanische Untersuchungen der Statischen und Dynamischen Compliance bei Normaldruckhydrocephalus. In: S. Leonhardt, K. Radermacher & T. Schmitz-Rode (ed.): 58, Aachener Beiträge zur Medizintechnik (ISBN 978-3-8440-7368-3), Shaker, 2020
- S.A.G.A. Grothues, M. Asseln & K. Radermacher: Variation of the femoral J-Curve in the native knee. In: F. Rodriguez Y Baena & F. Tatti (ed.): CAOS 2020. The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 4, 2020, pp. 86-91 [DOI: 10.29007/5k32]
- J. Habor: The Patient-specific Combined Target Zone for Total Hip Arthroplasty Planning. In: S. Leonhardt, K. Radermacher & T. Schmitz-Rode (ed.): 59, Aachener Beiträge zur Medizintechnik (ISBN 978-3-8440-7599-1), Shaker, 2020
- J. Heibeyn, A. Janß & K. Radermacher: Multimodal Touchless Human Machine Interface for an IEEE 11073 SDC Interconnected Surgical Workstation. Proceedings of the 3rd IEEE International Conference on Industrial Cyber-Physical Systems (ICPS), 1, 2020, pp. 437-441 [DOI: 10.1109/ICPS48405.2020.9274767]
- B. Hohlmann, J. Glanz & K. Radermacher: Segmentation of the distal femur in ultrasound images. Current Directions in Biomedical Engineering, 6(1), 2020, pp. 1-5 [DOI: 10.1515/cdbme-2020-0034]
- B. Hohlmann & K. Radermacher: Augmented Active Shape Model Search – towards 3D Ultrasound-based Bone Surface Reconstruction. In: F. Rodriguez Y Baena & F. Tatti (ed.): CAOS 2020. The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 4, 2020, pp. 117-121 [DOI: 10.29007/3px6]
- A. Janß, S. Schlichting & K. Radermacher: Operationssaal und Klinik 4.0 - Der OR.NET Ansatz. In: W. Frenz (ed.): Handbuch Industrie 4.0: Recht, Technik, Gesellschaft (Teil VI Medizin und Gesundheit), Springer, 2020, pp. 1053-1075 [DOI: 10.1007/978-3-662-58474-3_54]
- P. Schad, M. Wollenweber, J. Thüring, J. Schock, J. Eschweiler, G. Palm, K. Radermacher, F. Eckstein, A. Prescher, C. Kuhl, D. Truhn & S. Nebelung: Magnetic resonance imaging of human knee joint functionality under variable compressive in-situ loading and axis alignment. Journal of the Mechanical Behavior of Biomedical Materials, 2020, 110(103890) [DOI: 10.1016/j.jmbbm.2020.103890]
- P. Schleer, P. Kaiser, S. Drobinsky & K. Radermacher: Augmentation of haptic feedback for teleoperated robotic surgery. International Journal of Computer Assisted Radiology and Surgery, 2020, 15, pp. 515-529 [DOI: 10.1007/s11548-020-02118-x]
- P. Schleer, D. Körner, M. Vossel, S. Drobinsky & K. Radermacher: Conceptual design of force reflection control for teleoperated bone surgery. Current Directions in Biomedical Engineering, 6(1), 2020, pp. 1-5 [DOI: 10.1515/cdbme-2020-0014
- R.M. Sellei, J. Wollnitz, N. Reinhardt, M. de la Fuente, K. Radermacher, C. Weber, P. Kobbe & F. Hildebrand: Non-invasive measurement of muscle compartment elasticity in lower limbs to determine acute compartment syndrome: Clinical results with pressure related ultrasound. Injury, 2020, 51, pp. 301-306 [DOI: 10.1016/j.injury.2019.11.027]
- L. Theisgen, F. Strauch, M. de la Fuente & K. Radermacher: Catalogue of Hazards: A fundamental part for the safe design of surgical robots. Current Directions in Biomedical Engineering, 2020, 6(1), pp. 1-5 [DOI: 10.1515/cdbme-2020-0009]
- M. Vossel, K. Radermacher & M. de la Fuente: Evaluation of Motion Compensation Dynamics of the Handheld Robot MINARO HD. In: F. Rodriguez Y Baena & F. Tatti (ed.): CAOS 2020. The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 4, 2020, pp. 278-282 [DOI: 10.29007/4xbz]
- O. Yilmaz, D. Wieschebrock, J. Heibeyn, K. Radermacher & A. Janß: Development and Evaluation of a Platform-Independent Surgical Workstation for an Open Networked Operating Theatre Using the IEEE 11073 SDC Communication Standard. Digital Human Modeling and Applications in Health, Safety, Ergonomics and Risk Management. Posture, Motion and Health, 2020, pp. 79-92 [DOI: 10.1007/978-3-030-49904-4_6]