Publikationen

RWTH Aachen Universitätsbibliothek

  • A. Benninghaus, F. Huber, A. Müller & K. Radermacher: Experimental investigation of the influence of pathological blood dynamics on the CSF system with regard to normal pressure hydrocephalus. Abstracts from Hydrocephalus 2022: the Fourteenth Meeting of the Hydrocephalus Society, Fluids and Barriers of the CNS, 19(104), 2023 [DOI: 10.1186/s12987-022-00397-x]
  • P. Brößner, B. Hohlmann, K. Welle & K. Radermacher: Ultrasound-Based Registration for the Computer-Assisted Navigated Percutaneous Scaphoid Fixation. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2023, 70(9), pp. 1064-1072 [DOI: 10.1109/TUFFC.2023.3291387]
  • M. de la Fuente Klein, L. Theisgen, M. Vossel, K. Radermacher & G. Petasch: System for connecting end effectors to robot arms that operate under sterile conditions. U.S. patent No. US2023045591A1, 2023
  • S. Drobinsky, M. de la Fuente, B. Puladi & K. Radermacher: Accuracy of on-site teleoperated milling with haptic assistance. International Journal of Computer Assisted Radiology and Surgery, 2023, Onlinefirst [DOI: 10.1007/s11548-023-02983-2]
  • W.J. Frasier, R. Brik, R.P. Courtis, T. Yardibi, M. Puls, M. de la Fuente Klein, L. Theisgen, M. Vossel & K. Radermacher: Surgical robot with anti-skive feature. U.S. patent No. US2023020249A1, 2023
  • S. Grothues, A.-K. Becker, B. Hohlmann & K. Radermacher: Parameter-based patient-specific restoration of physiological knee morphology for optimized implant design and matching. Biomedical Engineering / Biomedizinische Technik, 2023, Onlinefirst [DOI: 10.1515/bmt-2023-0017]
  • S. Grothues, B. Hohlmann, S.M. Zingde & K. Radermacher: Potential for femoral size optimization for off-the-shelf implants: A CT derived implant database analysis. Journal of Orthopaedic Research, 2023, 41(6), pp. 1198-1205 [DOI: 10.1002/jor.25464]
  • E.-M. Haddouti, N. Reinhardt, R. Ossendorff, C. Burger, D.C. Wirtz, M. de la Fuente & F.A. Schildberg: Effects of single and repeated shock wave application on the osteogenic differentiation potential of human primary mesenchymal stromal cells and the osteoblastic cell line MG63 in vitro. Frontiers in Bioengineering and Biotechnology, 2023, 11, pp. 1-17 [DOI: 10.3389/fbioe.2023.1207655]
  • B. Hohlmann, P. Broessner, L. Phlippen, T. Rohde & K. Radermacher: Knee Bone Models From Ultrasound. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2023, 70(9), pp. 1054-1063 [DOI: 10.1109/TUFFC.2023.3286287]
  • M. Jörgens, L. Schröder, S. Grothues, J. Brunner, K. Radermacher, B.M. Holzapfel & J. Fürmetz: Open wedge high tibial osteotomy shows relevant im-pact on tibiofemoral and patellofemoral joint kinematicsof the knee in a multibody simulation model. Swiss medical weekly. Supplementum 269: Abstracts of the 83th annual meeting of swiss orthopaedics, 2023, 153(6), pp. FM031 [DOI: 10.57187/smw.2023.40106]
  • N. Reinhardt, C. Schmitz, S. Milz & M. de la Fuente: Influence of the skull bone and brain tissue on the sound field in transcranial extracorporeal shock wave therapy: an ex vivo study. Biomedical Engineering / Biomedizinische Technik, 2023, Onlinefirst [DOI: 10.1515/bmt-2022-0332]
  • R.M. Sellei, A. Beckers, P. Kobbe, A. Weltzien, C.D. Weber, C.K. Spies, N. Reinhardt, M. de la Fuente, K. Radermacher & F. Hildebrand: Non-invasive assessment of muscle compartment elasticity by pressure-related ultrasound in pediatric trauma: a prospective clinical study in 25 cases of forearm shaft fractures. European Journal of Medical Research, 2023, 28(296), pp. 1-7 [DOI: 10.1186/s40001-023-01232-1]
  • L. Theisgen, F. Strauch, M. de la Fuente Klein & K. Radermacher: Safe design of surgical robots – a systematic approach to comprehensive hazard identification. Biomedical Engineering / Biomedizinische Technik, 2023, 68(2), pp. 117-123 [DOI: 10.1515/bmt-2022-0202]
  • N. Wickel, M. Vossel, O. Yilmaz, K. Radermacher & A. Janß: Integration of a surgical robotic arm to the connected operating room via ISO IEEE 11073 SDC. International Journal of Computer Assisted Radiology and Surgery, 2023, 18, pp. 1639–1648 [DOI: 10.1007/s11548-023-02926-x]
  • O. Yilmaz, K. Radermacher, F. Beger, J. Roth & A. Janß: Usability evaluation of a process optimized integrated workstation based on the IEEE 11073 SDC standard. In: J. Kalra & N. Lightner (ed.): Healthcare and Medical Devices, 79, 2023, pp. 133-142 [DOI: 10.54941/ahfe1003481]

RWTH Aachen Universitätsbibliothek

  • P. Brößner, B. Hohlmann & K. Radermacher: Transformer vs. CNN – A Comparison on Knee Segmentation in Ultrasound Images. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 31-36 [DOI: 10.29007/cqcv]
  • J. Dell'Anna-Pudlik: Modellbasiertes Risikomanagement offen vernetzter Chirurgie-Systeme für eine zentrale konfigurierbare Fußbedieneinheit. In: S. Leonhardt, K. Radermacher & T. Schmitz-Rode (ed.): 70, Aachener Beiträge zur Medizintechnik (ISBN 978-3-8440-8597-6), Shaker, 2022
  • M.C.M. Fischer, P. Damm, J. Habor & K. Radermacher: Effect of the underlying cadaver data and patient-specific adaptation of the femur and pelvis on the prediction of the hip joint force estimated using static models. Journal of Biomechanics, 2022, 139, pp. 110526 [DOI: 10.1016/j.jbiomech.2021.110526]
  • M.C.M. Fischer, K. Tokunaga, M. Okamoto, J. Habor & K. Radermacher: Implications of the uncertainty of postoperative functional parameters for the preoperative planning of total hip arthroplasty. Journal of Orthopaedic Research, 2022, 40, pp. 2656-2662 [DOI: 10.1002/jor.25291]
  • M.C.M. Fischer: Morpho-functional Modelling for Preoperative Planning in Total Hip Arthroplasty. In: S. Leonhardt, K. Radermacher & T. Schmitz-Rode (ed.): 71, Aachener Beiträge zur Medizintechnik (ISBN 978-3-8440-8671-3), Shaker, 2022
  • S. Grothues, L. Berger & K. Radermacher: Automated analysis of morpho-functional interbone parameters of the knee based on three dimensional (3D) surface data. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 81-88 [DOI: 10.29007/8nb5]
  • S. Grothues & K. Radermacher: Criteria for Implant Fit Assessment in Total Knee Arthroplasty – A Review. Current Directions in Biomedical Engineering, 8(2), 2022, pp. 165-168 [DOI: 10.1515/cdbme-2022-1043]
  • S. Grothues & K. Radermacher: X-ray based morphological analysis of the knee - a review. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 89-98 [DOI: 10.29007/sqcb]
  • J. Heibeyn, O. Jansen, K. Wiese, F. Deinet, M. Roitsch, R. Stens, A. Janß & K. Radermacher: Ableitung von Anforderungen an eine AEMP-Benchmark. Zentralsterilisation, 2022, 30(5), pp. 228–234
  • J. Heibeyn, O. Jansen, A. Janß & K. Radermacher: Erstellung eines Vergleichskriterien-Katalogs für AEMP-Prozesse. Zentralsterilisation Abstractheft 25. Fachkongress der Aufbereitung von Medizinprodukten, 30, 2022, pp. 36-37
  • J. Heibeyn, N. König & K. Radermacher: Greifer zum Greifen von Objekten. German patent request DE102020118730A1, 2022
  • B. Hohlmann, M. Asseln, J. Xu & K. Radermacher: Investigation of Morphotypes of the Knee Using Cluster Analysis. The Knee, 2022, 35, pp. 157-163 [DOI: 10.1016/j.knee.2022.03.006]
  • B. Hohlmann, P. Brößner & K. Radermacher: CNN based 2D vs. 3D Segmentation of Bone in Ultrasound Images. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 116-120 [DOI: 10.29007/qh4x]
  • A. Janß, S. Schlichting & K. Radermacher: Operating Room and Clinic 4.0: The OR.NET Approach. In: W. Frenz (ed.): Handbook Industry 4.0: Law, Technology, Society, Springer Berlin Heidelberg, 2022, pp. 857-878 [DOI: 10.1007/978-3-662-64448-5_45]
  • P. Pandey, B. Hohlmann, P. Brößner, I. Hacihaliloglu, K. Barr, T. Ungi, O. Zettinig, R. Prevost, G. Dardenne, Z. Fanti, W. Wein, E. Stindel, F. Arambula Cosio, P. Guy, G. Fichtinger, K. Radermacher & A. Hodgson: Standardized Evaluation of Current Ultrasound Bone Segmentation Algorithms on Multiple Datasets. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 148-153 [DOI: 10.29007/q51n]
  • K. Radermacher & D. Steines: Kinematic and parameterized modeling for patient-adapted implants, tools, and surgical procedures. U.S. patent No. 11229519, 2022
  • N. Reinhardt & M. de la Fuente: Technical evaluation of a high energy burst wave device compared to single pulse shock waves. VI ISMST Basic Research Meeting, 2022
  • N. Reinhardt, C. Schmitz, S. Milz & M. de la Fuente: Influence of the Skull Bone and Brain Tissue on the Sound Field during Transcranial Shock Wave Treatment. VI ISMST Basic Research Meeting, 2022
  • N. Reinhardt, J. Wegenaer & M. de la Fuente: Influence of the pulse repetition rate on the acoustic output of ballistic pressure wave devices. Scientific Reports, 2022, 12(18060), pp. 1-7 [DOI: 10.1038/s41598-022-21595-5]
  • M. Vossel, L. Theisgen, K. Radermacher & M. de la Fuente: Accuracy Evaluation of Image-Based Virtual Fixtures in Robotic Laminectomy. In: F. Rodriguez Y Baena, J.W. Giles & E. Stindel (ed.): Proceedings of The 20th Annual Meeting of the International Society for Computer Assisted Orthopaedic Surgery, 5, 2022, pp. 180-184 [DOI: 10.29007/cr5c]
  • C. Castelar Wembers, F. Flürenbrock, B. Maurer, A. Benninghaus, K. Radermacher & S. Leonhardt: A mechatronic test-bench to investigate the impact of ventricular pulsation in hydrocephalus. Biomedical Signal Processing and Control, 2022, 75, pp. 103579 [DOI: 10.1016/j.bspc.2022.103579]
  • O. Yilmaz, A. Janß & K. Radermacher: Applying User Interface Profiles to Ensure Safe Remote Control within the Open Networked Operating Room in accordance with ISO IEEE 11073 SDC. In: J. Kalra & N. Lightner (ed.): Healthcare and Medical Devices, 51, 2022, pp. 24-30 [DOI: 10.54941/ahfe1002094]